BAUER 110 KVA aggregaat

BAUER 110 KVA aggregaat
BAUER 110 KVA aggregaat
  • Category: we take care of the transport - shipping - customs documents if necessary
  • Brand: BAUER
Max. power [kW/kVA/PS] 88 / 110 / 119.65
Continuous power [kW/kVA/PS] 80 / 100 / 108.77
Nominal voltage [V] 230 / 400
Frequency [Hz] 50
Speed ​​[rpm] 1500
Power factor [cos φ] 0.8

Dimensions and weight of the housing:
Dimensions L x W x H [mm] approx. 2950 x 1100 x 1280
Weight dry approx. [Kg] 1530
Tank capacity [L] 135
Housing lockable Yes
Transport device forklift pockets [outside distance 1.00m] / crane eyes
Housing colours RAL 7012 / RAL 3000

Autonomy:
Duration [approx. hours] 8-10 per tank filling

Operating noise:
Sound pressure level LPA [7m] [db(A)] 75

Engine:
Ricardo brand
model ZH6105ZLD/100KW
fuel type diesel
emission level Non-emission certified
number of cylinders 6
displacement [L] 6.49
compression ratio 16:1
bore x stroke [mm x mm] 105 x 125
CO² emissions n/a (Stage III)
CO² test procedure n/a (Stage III)
four-stroke cycle
Speed ​​controller mechanical
Speed ​​[rpm] 1500
Starter Electric with battery
On-board voltage [V] 12V / 24V
Battery voltage [Ah] 230 / 400
Cooling system water cooling
Thermostat (°C) 71-85
Maximum water temperature 98
Exhaust system soundproof
Maintenance interval 1 x per year or every 250 operating hours (whichever comes first)
Filter and oil change once per year or every 250 operating hours (whichever comes first)

Generator:
Stamford brand
Model name YHG/80kW 1500 rpm
Generator system Brushless, self-winding, AVR with automatic voltage regulation, 100% copper wire winding
Synchronous generator type
insulation class H
Voltage regulation Electronic
IP protection class 23
Number of phases 3
frequency 50 Hz
Frequency tolerance ≤ ± 1%
Voltage stability at speed deviation -5% +30% (%) 1
Power factor 0.8 cos φ (lag)
voltage regulator AVR
Output mode 3 phase conductors / 1 neutral conductor
Outputs 1 x CE 1-phase 16A / 1 x CE 3-phase 16A / 1 x CE 3-phase 32A / Terminal block for direct house power or ATS
Main switch Main switch
Protection class IP23
Altitude ≤ 1000m
Excitation system Brushless, self-winding, AVR with automatic voltage regulation, 100% copper wire winding
TT network type
Telephone influence factor (TIF) ≤ 50
Tetrahydrofuran ≤ 2%
Voltage regulation, steady state ≤ ± 1%
Transient voltage ≤ -15%~+20%

Control panel:
SmartGen brand
Model name HGM 6120N
LCD display Resolution 132 x 64 pixels Backlight
Adjustable display languages: Chinese, English, Spanish, Russian, Portuguese, Turkish, Polish and French
Operation Physical push buttons
Acrylic glass screen
Screen and buttons Silica gel panel and buttons can be used for safe operation during temperature fluctuations
Connections via plug-in connectors RS485 communication port, can perform 3 external functions via MODBUS protocol.
CANBUS port, connected to the electronic injection with J1939, for monitoring commonly used parameters (water temperature, oil pressure, speed and fuel consumption, etc.), for controlling start, stop and speed (controller with CANBUS port is required)
Via CANBUS connection Suitable for 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC grid., Measurement of 3-phase voltage, 3-phase current, frequency, performance parameters of grid/generators.
With PCL Editor, the user has access to configurable functions to meet specific application requirements.
Monitoring function The operating status, error conditions and measured values ​​are displayed on the LCD screen and the LEDs on the front

Consumables:
We use the following raw materials in OEM quality. Please ensure that you use or replace them with ones that are at least technically equivalent. If you have any further questions, please refer to the FAQ on consumables and/or contact your mineral oil supplier or petrol station.
Oil/tank capacity in litres ROWE Hightec Formula Super SAE 15W-40 / 13 litres
Antifreeze / Tank capacity in litres ROWE Hightec Antifreeze AN-SF 12+ / 22 litres *
Fuel / Tank capacity in litres Premium Diesel** depending on availability / 135 litres
* With a mixing ratio of 1:1, 50% of the tank volume in water or antifreeze is required.
:
: